← All guided checks
TROUBLESHOOTING WORKSHOP

SWR too high?

Separate measurement setup, cable and antenna before changing antenna length.

Switch the transmitter off before working on the RF path. Never connect a VNA to a transmitting output. Consult each device’s manual for permitted power and SWR limits.

CHECK 4

What does a suitable known matched load show?

Connect the load at the selected measurement plane. Impedance and frequency range must match; transmit tests also require adequate power and duty ratings. A VNA calibration load is not a power dummy load.

Show check record
HB3YAQ · Check record: SWR too high?
Your answers; no automatic measurement.

1. Do cable, connectors and antenna connection look sound?
→ Yes, nothing visibly wrong
2. How are you measuring SWR?
→ With a VNA or antenna analyser
3. Is reflection measurement calibrated for this setup?
→ Yes, at the intended measurement plane

What does a suitable known matched load show?
Connect the load at the selected measurement plane. Impedance and frequency range must match; transmit tests also require adequate power and duty ratings. A VNA calibration load is not a power dummy load.

/en/troubleshooting/high-swr?path=intact,vna,calibrated#check