← All toolsAntennas & feed lines · CALCULATOR

Quarter-wave impedance transformer

Line impedance and length between two resistive impedances.

HB3YAQ · Ajdin HadzicLearning to take awayhttps://hb3yaq.ch/en/tools/transformer
View saved items →Only in this browser

Loading calculator …

THE CALCULATION

Formula & context

Zt = √(R₁R₂); L = c · VF/(4f)

A lossless quarter-wave line transforms a resistive load according to Zin = Zt²/Rload. The geometric mean of the resistances gives the required line impedance.

A worked example

An ideal match between 50 and 100 Ω requires 70.71 Ω. Length then depends on frequency and VF.

UNDERSTANDING THE MODEL

Assumptions & limits

Narrowband match for resistive impedances. Complex antenna impedances need additional treatment; an arbitrary cable does not replace the calculated impedance.

Impedance and matchingUnderstand the reasoning →

From reading to experimenting

Quarter-wave impedance transformer

An ideal match between 50 and 100 Ω requires 70.71 Ω. Length then depends on frequency and VF.

Open example with starting values →Side A impedance: 50 Ω · Side B impedance: 100 Ω · Frequency: 14.2 MHz · Velocity / shortening factor: 0.66 Back to the learning article →

Then change exactly one value. Compare the result and use the formula to explain why it changes. The model limits below the calculator also apply here.

Sources & further documentation