HB3YAQLucerne
Original software image. The settings shown belong to the product illustration, not to my station.
Icom · Adjustment software
CS-F4029ADJ
Separate service adjustment software for the Icom IC-F4029SDR.
At a glance
All specifications ↓- PC interface
- RS-232C, 9-pin D-sub, or USB
- Software version in manual
- Revision 1.0 or later
- Target radio
- IC-F4029SDR
- Historical operating systems
- Windows 98 / 98SE / Me / 2000 / XP
- Service cable
- Modified OPC-478/U as specified in the manual
My radio for this software
Inventory and assignments reflect my collection.
Icom service manual (PDF) ↗CS-F4029ADJ is Icom’s adjustment software for technical alignment of the IC-F4029SDR. It works with the radio’s calibration and alignment values and is documented from revision 1.0 onward. Required preparation data is first loaded using CS-F4029DR.
Alignment requires a test bench. Icom lists a regulated 7.2 V supply, RF power meter, signal generator, frequency counter, deviation meter and oscilloscope, among other equipment. The OPC-478/U is used as a suitably modified service lead. Published Windows requirements come from the original documentation and do not confirm compatibility with current operating systems.
Features & equipment
- Technical radio alignment following the service procedure.
- Preparation through CS-F4029DR.
- Alignment in conjunction with external test equipment.
- Documented service lead based on OPC-478/U.
Specifications
Documented requirements
- Software version in manual
- Revision 1.0 or later
- Target radio
- IC-F4029SDR
- Historical operating systems
- Windows 98 / 98SE / Me / 2000 / XP
- PC interface
- RS-232C, 9-pin D-sub, or USB
- Service cable
- Modified OPC-478/U as specified in the manual
- Bench supply
- 7.2 V DC, greater than 1 A
- RF power meter
- 0.1–1 W, 100–600 MHz, 50 Ω, SWR better than 1.2:1
- Additional test equipment
- Signal generator, frequency counter, deviation meter, oscilloscope and attenuator as specified in service manual
Documents & sources
- Icom – service manual, requirements and procedure (opens in a new tab)Original documentation
- Icom – service manual with addendum (opens in a new tab)Original documentation